We offer Powerblast Dynamo Condenser Type Exploder to our valuable customers. Our range is available in different capacities based on the requirements of our client and the blasting equipment offered by us are high performance, accurate results, sturdiness and longer functional life.
Features:
Tested by the Central Mining And Research Station Dhanbad as per IS 9836-1981
Powerblast Exploder has inbuilt circuit Continuity tester
Powerblast Exploder Is provided with charging meter to indicate the charge developed when the generator handle Is rotated
PowerblastExploder gets internally discharged when the generator handle is removed from the flange
Powerblast Exploder will discharged internally if the firing is to be cancelled by turning the operating key to the "OFF" position
Powerblast Exploder is very compact and has high impact plastic moulded body
Operation:
Connect shot firing cable to the Exploder output terminals. insert handle in to the generator flange and rotate. If the detonator circuit has proper continuity, the continuity test indicator will glow. If It does not glow remove handle and check detonator circuits.
Press firing switch to explode when the pointer of the charging meter goes to the red scale.
If the firing is to be cancelled remove handle from the generator flange, and the condenser of the Exploder will discharge internally.
Instruction For Use:
The Exploder is put on a solid base and the generator handle is rotated for charging and circuit continuity testing
Firing switch Is pressed to explode when charging meter pointer is on the red scale and the continuity tester indicator Is glowing
Keep Exploder in dry place
Checking:
The Capacity of The Powerblast Exploder may be tested by the specially made Powerblast Exploder Tester. The Exploder Needs no special maintenance
We are majorly looking queries from Africa, Australia and America
We offer Digital Electronic Permitted Type Exploder to our customers. These are high demand in the market and they have been made using the best technology available in the market.
Features:
Powerblast Exploder will not charge if the connected circuit has higher resistance then recommended, or the circuit is open.
Powerblast Exploder does not fire till the rated output is attained, when the firing switch is pressed.
Powerblast Exploder is provided with low battery indicator which gives warning that the battery is low and gets internally locked till the battery is replaced or charged.
Powerblast Exploder will discharged internally If the firing is to be cancelled by turning the operating key to the "OFF" position.
Powerblast Exploder Is very compact and has high impact plastic moulded body.
Powerblast Exploder is very simple to operate:
First check the instrument by inserting the key and turning it clockwise for the condition of the battery."L" indicates low battery and dot (.) indicates that the exploder is " ON "
Connect the external circuit leads to the exploder output terminals.
By turning the inserted key clockwise the letter "C" will appear on the dial indicating that the circuit is In order.
Keep the key in clockwise position until the letter "F" start flashing.
Press firing switch to explode.
Instruction For Use:
Insert operating key and turn clockwise to 60, the Exploder will indicate "C" & then "F" starts flashing when full charge is attained. Press firing switch to explode
Replace OR charge battery for 16 hours continuously when low battery indicator starts flashing
Checking:
The capacity of the Exploder may be tested by special powerblast Exploder tester.
We are majorly looking queries from Africa, Australia and America.
Technical Specification:
Max. Circuit Resistance
160 Ohms with cable
Firing Current
1.2 Amps.
Energy
1.21 Ws
Firing Tension
510 Volts.
Duration of Firing Current
< 4 ms at 160 Ohms Circuit Resistance
Continuity Sensing Voltage & Current
Open Circuit Voltage - 5 Volts
Short Circuit Current - 5 Ma Max.
Batteries
AA Type Alkaline / NI-CD / NI-MH /LI-ION with minimum 700 Mah capacity. (6 Nos.)